R-Value Reference Chart
Recommended retrofit insulation levels by U.S. climate zone, and a way to estimate the R-value of insulation already in an attic from its type and depth. These figures come from ENERGY STAR; they are not a substitute for the adopted local energy code or a product label.
What R-value means
R-value measures how well a material resists heat flow. A higher number means more resistance. ENERGY STAR notes that recommended levels vary by climate and by where in the house the insulation goes. Layers in series are often added together when they are installed as intended, but compression, gaps, and air leaks reduce real-world performance. Always prefer the R-value printed on the product.
ENERGY STAR recommended levels for retrofits
The table below is ENERGY STAR’s recommended insulation for retrofitting existing wood-framed buildings. ENERGY STAR states that this guidance is based on the 2021 International Energy Conservation Code (IECC) Residential Provisions, Table R402.1.3. “Floor” is a floor over an unconditioned space. These are recommended add-up-to (or add) levels in the ENERGY STAR table, not a site-specific design.
| Climate zone | Add insulation to an uninsulated attic | If the attic already has 3–4 inches of insulation, add | Floor |
|---|---|---|---|
| 1 | R-30 | R-25 | R-13 |
| 2 | R-49 | R-38 | R-13 |
| 3 | R-49 | R-38 | R-19 |
| 4A and 4B | R-60 | R-49 | R-19 |
| 5, 6, and 4C | R-60 | R-49 | R-30 |
| 7 and 8 | R-60 | R-49 | R-38 |
Source: ENERGY STAR, “Recommended Home Insulation R-Values,” based on the 2021 IECC Table R402.1.3. Confirm your climate zone from an official IECC or DOE climate-zone map, and confirm the adopted code in your jurisdiction.
Walls, basements, and crawlspaces (same ENERGY STAR page)
When exterior siding is removed on an uninsulated wood-frame wall, ENERGY STAR says to blow insulation into the empty cavity before the new siding, and then add insulative wall sheathing: R-5 in zone 3, and R-5 to R-10 in zones 4–8. On an already insulated 2×4 wood-frame wall, ENERGY STAR suggests adding R-10 insulative sheathing in zones 4–8.
For basement or crawlspace walls: zone 3, add R-5 insulative sheathing or an R-13 batt; zones 4A and 4B, R-10 sheathing or an R-13 batt; zones 4C and 5–8, R-15 sheathing or an R-19 batt. ENERGY STAR does not give a parallel wall recommendation for zones 1 and 2 on that table.
Estimate the R-value of insulation already in an attic
ENERGY STAR’s DIY inspection page says: measure the depth in inches, identify the type, and multiply by the factor in this table. The result is an estimate of existing R-value, not a laboratory test.
| What you see | What it probably is | R-value estimate |
|---|---|---|
| Loose fibers, light-weight yellow, pink, or white | Fiberglass (loose-fill) | 2.5 × depth in inches |
| Dense gray or near-white loose fibers, maybe with black specs | Rock wool (loose-fill) | 2.8 × depth in inches |
| Small gray flat pieces or fibers (from newsprint) | Cellulose | 3.7 × depth in inches |
| Light-weight granules | Vermiculite or perlite | 2.7 × depth in inches |
| Batts, light-weight yellow, pink, or white | Fiberglass batts | 3.2 × depth in inches |
Source: ENERGY STAR, “What to Look For: DIY Checks and Inspections.” ENERGY STAR also warns that some attics have vermiculite, which may contain asbestos — do not disturb vermiculite unless it has been tested by an approved lab.
Example: 6 inches of loose-fill fiberglass is about 2.5 × 6 = R-15 on this table. In climate zone 5, ENERGY STAR recommends adding R-49 if you already have 3–4 inches, or bringing an uninsulated attic to R-60. The attic insulation calculator applies the same multipliers and can estimate bags from a published blown-in chart.
Foam and other products
The ENERGY STAR DIY table above does not list rigid foam or spray foam. A 2008 U.S. Department of Energy insulation fact sheet suggests, when no label is visible, multiplying foam board or sprayed-on foam thickness in inches by 5 as a rough estimate, and multiplying a fiberglass batt by 3.2 — the batt factor matches ENERGY STAR. Treat the “times 5” foam rule as an older DOE rule of thumb only. Current foam R-values vary widely by product; use the label.
Sources
- ENERGY STAR, Recommended Home Insulation R-Values (retrofit table; based on 2021 IECC Table R402.1.3).
- ENERGY STAR, DIY Checks and Inspections (depth multipliers and vermiculite caution).
- U.S. Department of Energy, Insulation Fact Sheet (DOE/CE-0180, 2008), archived at Oak Ridge National Laboratory, for the optional foam “multiply inches by 5” estimate: DOE/CE-0180 PDF.
Disclaimer: These tools give planning estimates only. Coverage, sheet sizes, batt dimensions, bag yields, and R-values vary by product, surface, installation, and climate. Always check the label or data sheet for the product you buy, and follow the adopted local building code and a qualified professional for any code-regulated, fire-rated, moisture, or structural work. Interior Reference is not a contractor, retailer, or building-code authority, and it does not replace manufacturer instructions or a licensed designer.