Estimate Attic Insulation Quantity

Work out attic floor area, an estimate of the R-value already there, and a bag count for reaching a target R-value from bare. The example bag chart is from a published manufacturer data sheet; enter your own bags-per-1,000 sq ft figure when you have the label.

Calculator

Attic floor area is length × width, or a total area you enter. Existing R-value, if you measure depth, uses ENERGY STAR’s DIY multipliers (for example, loose-fill fiberglass ≈ 2.5 × depth in inches). The example bag counts use Owens Corning AttiCat PINK blown-in insulation, 27.5 lb bags, from the May 2026 product data sheet — bags per 1,000 sq ft and a minimum thickness, for a labeled R-value from a bare (or as-labeled) condition. This is not Owens Corning’s official calculator. Switch to “custom bags per 1,000 sq ft” and type the number from the product you are buying.

Formula, chart, and example

Bags = (attic area ÷ 1,000) × bags per 1,000 sq ft, then round up to a whole bag. On the example AttiCat chart, both the bag count and the minimum thickness must be met for the labeled R-value.

Labeled R-value Bags per 1,000 sq ft Maximum coverage per 27.5 lb bag (sq ft) Minimum thickness (in)
R-135.9169.85
R-199110.77
R-2210.594.88
R-2612.679.39.5
R-3014.668.510.75
R-381952.613.5
R-4422.444.615.5
R-492539.917
R-6031.531.820.5

Source: Owens Corning AttiCat PINK Blown-In Insulation product data sheet, Pub. No. 10011273-L, May 2026, 27.5 lb nominal bag weight. Other brands and bag weights have different charts.

Example: a 40 ft × 25 ft attic is 1,000 sq ft. For R-49 from bare on this chart, bags = (1,000 ÷ 1,000) × 25 = 25 bags, at a minimum 17 in thickness. In climate zones 2 and 3, ENERGY STAR recommends R-49 for an uninsulated attic; in zones 4–8 it recommends R-60 (31.5 bags per 1,000 sq ft on this same chart, which rounds up to 32 bags for a 1,000 sq ft attic).

If insulation is already present, the bag chart is still a “from bare” (or as-labeled) thickness chart. A top-up is not the same as the R-49 or R-60 row. ENERGY STAR multipliers can still estimate what you already have. Do not disturb vermiculite until it has been tested for asbestos, as ENERGY STAR warns.

Keep insulation away from unrated recessed fixtures and from flues and chimneys, following the product instructions and local code. The AttiCat data sheet also states that both bag count and minimum thickness are required for the labeled R-value.

Sources

Disclaimer: These tools give planning estimates only. Coverage, sheet sizes, batt dimensions, bag yields, and R-values vary by product, surface, installation, and climate. Always check the label or data sheet for the product you buy, and follow the adopted local building code and a qualified professional for any code-regulated, fire-rated, moisture, or structural work. Interior Reference is not a contractor, retailer, or building-code authority, and it does not replace manufacturer instructions or a licensed designer.